page 1
page 2
page 3
page 4
page 5
page 6
page 7
page 8
page 9
page 10
page 11
page 12
page 13
page 14
page 15
page 16
page 17
page 18
page 19
page 20
page 21
page 22
page 23
page 24
page 25
page 26
page 27
page 28
page 29
page 30
page 31
page 32
page 33
page 34
page 35
page 36
page 37
page 38
page 39
page 40
page 41
page 42
page 43
page 44
page 45
page 46
page 47
page 48
page 49
page 50
page 51
page 52
page 53
page 54
page 55
page 56
page 57
page 58
page 59
page 60

33 Diagnostic Tests Witness ® LH Luteinizing Hormone Diagnostic Test Ovassay ® Plus System Ovassay ® Plus System is the easiest and most accurate in- clinic, faecal flotation method for identifying gastrointestinal parasites. A clean faecal testing system with accuracy and safety in mind. The test can be used for detection of intestinal parasitic eggs in bovine, ovine, caprine, equine, canine or feline faeces. Zinc Sulfate flotation media is a solution which floats parasitic ova as well as Giardia cysts. Increased filter area for improved detection of low- level ova burdens. Client- friendly collecting procedure assures compliance with easy to follow sampling instructions and hands off collection. The device is 100% sealable and disposable. Overflow Reservoir to assure a non- spill test which will reduce exposure to potentially hazardous samples. . Units: 50 tests and zinc sulfate . Sample type: Feaces . Test Time: 10 minutes . Storage: Room Temperature - 7 - 6 - 5 - 4 - 3 - 2 - 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Fertile Period Ovulation LH Surge Example of the Canine Estrus Cycle Progesterone Witness ® LH was designed to pinpoint the optimum time for canine breeding. Since its inception, LH testing has a proven variety of uses in multiple species. During the canine estrus cycle, the LH surge may occur from days 3 to 28 ( average days 3 to 12) after observable signs of heat and lasts approximately 24 hours. Ovulation occurs 2 days after the LH surge. Ova then require an additional 2 to 3 days to mature into a stage that will support fertilization. The fertile period of the bitch falls between days 4 and 7 after the LH surge with the most fertile days being 5 and 6 ( the day of the LH surge is counted as Day 0). Determining the LH surge is perhaps the most critical factor in reproductive efficiency. . Determine Ovulation . Improve Procedure Scheduling . Increase Conception Rates . Predict Whelping Dates . Assess Ovarian Status WD1118 Pack of 30 WD1109

34Diagnostic Tests FluDETECT ® Ag Test Strip for Swine Flu FluDetect for Swine Flu detect all 16 HA subtypes including new A/ H1N1 pandemic and HPAI H5N1 viruses. It detects H3N2 virus in pig nasal swab samples as early as day 1 post infection. FluDETECT ® Ag Test Strip for Equine Flu Influenza Type A viruses can infect horses and subtypes H3 and H7 are associated with this disease. This easy to use test is an in vitro, rapid immuno- migration assay designed to aid in the qualitative detection of Equine Influenza Virus in nasopharyngeal samples from symptomatic horses. The test detects all subtypes of Equine flu Type A. The test strip uses two antibodies that are specific to the p56 nucloprotein of Influenza Virus Type A. Anti-influenza A antibody bound to Influenza A antigen present in the sample forms a complex, which migrates along a strip and is captured on a sensitized reaction line by the second antibody. The accumulation of the complex causes the formation of a clearly visible pink/ purple band. The presence of a control band, located above the reaction line, ensures that the test was performed correctly. Easy to use in 4 simple steps: Step 1 Step 2 Step 3 Step 4 . Place test tube in rack . Add 8 drops (~ 250µl) extraction buffer into test tube . Insert test strip, labeled side up, so that pink pad is just submerged into extracted sample . Incubate for 15 minutes . Remove strip and read results . Insert swab sample into FluDETECT T extraction buffer . Rotate swab 5- 10 times in buffer . Press swab against side of tube to extract liquid. . Dispose of swab . Reading results and validation . Control line at top, closest to handle . Absence of control line indicates invalid test Kit contains: . 1 test tube rack ( for 5 tubes) . 1 dropper bottle containing extraction buffer ( 6ml) . 20 test tubes and caps . 20 swabs . 1 vial containing 20 test strips Kit contains: . 1 test tube rack ( for 5 tubes) . 1 dropper bottle containing extraction buffer ( 6ml) . 5 test tubes and caps . 5 swabs . 1 vial containing 5 test strips www. woodleyequipment. com